Haematology Controls and Calibrators: What to Order and How Much
Control blood and calibrators decide whether an FBC analyser can be trusted, and they have the shortest dating of anything on the bench. What to order for your analyser, how vial stability sets the size of each order, how to keep the cold chain to East Malaysia, and what to ask the supplier.
Three different purchases
Controls, calibrators and EQA samples are all blood-like materials with known values, but you buy them for different jobs and on different schedules. How to run controls and when to calibrate are covered in our quality-control and calibration guides; this page is about what to order.
| Item | What it is for | How often you buy it |
|---|---|---|
| Control blood | Checks the analyser every day before patients; never used to adjust it | Every few weeks, as each lot’s stability runs out |
| Calibrator | Adjusts the analyser’s calibration factors at installation, at the maker’s interval and after major repairs | Only when a calibration is due — it has the shortest dating of all |
| EQA samples | Unknown samples from an external scheme, compared with other laboratories | An annual subscription, with samples sent in rounds through the year |
Read next Running daily QC and Levey-Jennings chartsCalibrators vs controls, and when to recalibrate
Match the control to your analyser
Haematology controls are made from processed blood cells that behave like patient samples on the analyser. Their target values are assigned for each analyser model and each lot, and listed on the lot’s assay sheet. A control without values for your exact analyser cannot tell you whether it is working.
Levels
Most haematology controls come in three levels — low, normal and high — so you check the analyser near the decision points as well as in the middle. Order the levels your analyser maker recommends.
3-part or 5-part
A control assayed for a 3-part analyser gives targets for the three white-cell groups only. A 5-part analyser needs a control with assigned values for all five cell types, and reticulocytes or nucleated red cells if you report them.
Model and software
Check that your analyser model appears on the assay sheet, and ask whether the values change after a software update or between sample modes, such as whole blood and pre-diluted.
Haemoglobin meters
Point-of-care haemoglobin meters use their own liquid controls, made for specific meters, not FBC control blood.
Choosing a haemoglobin meterStability decides how much to order
Haematology controls are made with real cells, so they expire quickly. Each one has two limits: closed-vial stability, from manufacture until you open it, and open-vial stability, from opening until you discard it. These are examples from one maker’s published range; check the insert for the product you are offered.
- Closed-vial dating runs from manufacture, so a lot often reaches Malaysia with weeks already used. Agree a minimum remaining shelf life at delivery.
- You cannot stock up: with a 75-day closed-vial life, more than about two months’ supply is likely to expire on the shelf.
- With 7-day open-vial stability and daily QC, you open a new set roughly every week — four or five sets a month.
- With 30-day open-vial stability, one set a month is usually enough, provided each vial holds enough for all your runs.
- Check the volume each run uses against the vial fill volume, especially if you run controls more than once a day.
- Order calibrator only when a calibration is booked: with five days open and 45 days closed, it cannot sit in the fridge waiting.
- Overlap lots: run a new control lot alongside the old one for several days to set its targets before the old lot runs out.
| Product (use) | Open vial | Closed vial |
|---|---|---|
| Para 12 Extend (3-part analyser control) | 30 days | 190 days |
| Para 12 Plus (5-part control for a specific analyser) | 7 days | 75 days |
| Retic-Chex II (reticulocyte control) | 14 days | 75 days |
| HQ-Chex (haemoglobin and glucose meter control) | 30 days | 180 days |
| Cal-Chex (calibrator) | 5 days | 45 days |
Keeping the cold chain — including to Sabah and Sarawak
Most haematology controls and calibrators are stored at 2–8 °C, and most labels say not to freeze them. Heat or freezing damages the cells, and the damage shows up as a QC failure that looks like an analyser fault.
- Ask how the supplier ships: an insulated box with cold packs, and a temperature indicator or logger for longer journeys.
- Air freight to East Malaysia adds transit time. Order earlier, and avoid deliveries that sit in a depot over a weekend or public holiday.
- On arrival, check the temperature indicator, the lot, the expiry date and the appearance described in the insert. Record it, and refuse a delivery that failed the cold chain.
- Store controls in a monitored fridge, never in the door, and not with food.
- Bring vials to room temperature and mix them exactly as the insert says before use. Most say mix gently by inversion, not by shaking.
- Write the opening date on every vial, and discard it at the end of its open-vial life even if some is left.
Manufacturer or third-party controls, and EQA
For external quality assessment, the Department of Standards Malaysia’s specific criteria for medical testing (SC 2) set an order of preference: a scheme accredited to ISO/IEC 17043 first, then a recognised scheme, then comparisons between accredited laboratories, and only then comparisons between non-accredited laboratories. Malaysian hospital laboratories report enrolling in RCPAQAP, the Royal College of Pathologists of Australasia programme, for full blood count and related haematology surveys.
Manufacturer controls
Made for the maker’s own analysers, and sometimes required by a reagent rental or warranty agreement. Read the contract before changing.
Reagent rental terms that tie you to one supplierThird-party controls
Independent controls assayed for many analysers. MS ISO 15189 asks laboratories to consider independent control material, either instead of or in addition to the manufacturer’s, because it can expose a problem the matched reagent and control may share.
Peer comparison
Some control makers run peer-group programmes that compare your QC results with other laboratories using the same lot and analyser.
- Ask each EQA scheme which parameters it covers — FBC, differential, reticulocytes — and how often samples are sent.
- Check that samples can be shipped to your state, and how long they take.
- Ask whether the scheme is accredited to ISO/IEC 17043.
- Even a GP clinic can enrol. It is good practice for any site that reports results, and required for accreditation.
Questions to ask the supplier
- Which control and calibrator products are assayed for our exact analyser model and software version?
- What are the open- and closed-vial stabilities, and what minimum remaining shelf life will each delivery have?
- Can you deliver on a standing monthly schedule, and how do you ship to our state?
- What happens if a delivery arrives warm or late — replacement, and at whose cost?
- Are controls and calibrators inside a reagent rental or service contract, or priced separately?
- Who calibrates the analyser, and is the calibrator supplied for our own use?
- Are the controls and calibrators registered with the MDA? Ask for the numbers and check them on the public register.
Read next How to vet a haematology analyser supplierReagents: storage, stability and supply planning
Related guides
Hematology Analyser supply near you
Written quotes for clinics across Malaysia, handled from Batu Caves, Kota Kinabalu and Kuching.
- Hematology Analyser Kuala LumpurKuala Lumpur
- Hematology Analyser SelangorSelangor
- Hematology Analyser Petaling JayaSelangor
- Hematology Analyser Shah AlamSelangor
- Hematology Analyser KlangSelangor
- Hematology Analyser SerembanNegeri Sembilan
- Hematology Analyser MelakaMelaka
- Hematology Analyser Johor BahruJohor
Sources and further reading
- Streck. Hematology and linearity controls brochure: open- and closed-vial stability by product
- Department of Standards Malaysia. SC 2: Specific criteria for accreditation in the field of medical testing, Issue 6 (25 July 2024)
- Haematological reference intervals in a multiethnic population (Malaysian laboratory enrolled in RCPA programmes). PLoS One 2014;9:e91968
- RCPAQAP — Royal College of Pathologists of Australasia Quality Assurance Programs
- Medical Device Authority. Malaysia Medical Device Register: registered devices and licensed establishments
Frequently asked questions
How many levels of haematology control do I need?
How long does an opened haematology control last?
Can haematology controls be frozen?
Can I use a control from another brand on my analyser?
How often do I need to buy calibrator?
Does a GP clinic need EQA?
Get a written quotation